HONGYANG GROUP Somalia Technical Center

Fax: +86 (577)88097280

HONGYANG Group logo

HONGYANG GROUP Somalia Technical Center , Discuss Technical Problem , Suply After Service Online of Fuel Dispenser, Please Regist Firstly

D-GC8 FUEL DISPENSER

D-GC8

D-GC8 FUEL DISPENSER

Pump Type :Optional

Inlet Pressure : >=54kPa.

Flow rate (L/min.) :55±5

Suction Distance (m) :6(verticalmente) / 50(orizzontalmente)

FlowMeter Type :Optional

Accuracy : ±0.2%

Motor Voltage(V): 110V/220V/380V,50Hz/60Hz

Capacity(hp):1HP(0.75kw)

Input Voltage : 110V/220V/380V,50Hz/60Hz

Nozzle :Auto Shut-off Nozzle

Environmental Condition : -40~~+55degree

Control Type : Solenold Vale Control Type

Preset :Function Provided(Small LCDIndicator)

Display(Counter) :Type LCD and Bright Backlight

Digit of Volume :0~~999,999(6 Digits),Decimal point can be changed

Digit of Amount :0~~999,999(6 Digits),Decimal point can be changed

Digit of Unit price : 0~~9999(4 Digits),Decimal point can be changed

Digit of Total Range :0~~99,999,999,99

Optional :Display Type LCD and Bright Backlight

Digit of Volume : 0~~99,999,999(8 Digits),Decimal point can be changed

Digit of Amount : 0~~99,999,999(8 Digits),Decimal point can be changed

Digit of Unit price : 0~~999999(6 Digits),Decimal point can be changed

Digit of Total Range :0~~99,999,999,99

Totalizer :1~~9,999,999

Hose :4.5m

Weight : 425kg

Dimension(L×W×H) : 1615 X 620 X2420(mm)

Dimension(L×W×H)Of Qty of Container :40ft: 26

products links

links

technical archives

    Chapter I Fuel dispenser survey Article I General survey about fuel dispenser’s designation Article II Fuel dispenser’s development history Article III Basic function and category Article IV Basic working principle and configuration of fuel dispenser Chapter II Hydraulic components of fuel dispenser Article I Fuel pump Article II Vapor Separator Article III Measurement transducer Article IV Nozzle Article V Oil indicator Article VI Solenoid valve Article VII Hydraulic pipeline Chapter III Electric control system of fuel dispenser Article I Main functions of electric control system for fuel dispenser Article II Electric control system configuration of fuel dispenser Article III Card-controlled fuel dispenser Article IV Card-controlled dispenser and reader working flow Article V IC card filling system security Chapter IV Safety and environmental protection in forecourt Article I Lightning-proof Article II Wiring system Article III Earth wire and grounding system Article IV Vapor-Recovery system Chapter V Installation & debugging of fuel dispenser Article Installation Article II Submersible pump type dispenser and its installation Chapter VI Metrological approval of fuel dispenser Article I Metrological management and technical requirements Article II Appraisal condition and apparatus Article III Indicating appraisal methods and data processing Article IV Important notices in appraisal Chapter VII Failure and Troubleshooting A fuel dispenser rticle I Failure judgment and troubleshooting Article II Pipeline failure and maintenance Article III Important notices to dispenser’s maintenance Article IV Dispenser’s maintenance Chapter I Fuel dispenser survey Article I General survey about fuel dispenser’s designation 1. Fuel dispenser The full name is fuel dispenser for motor vehicles, used for measuring fuel of vehicles. It consists of meter for volumes of liquids, additional devices, and ancillary devices. 2. Liquid-volume meter Liquid-volu fuel dispenser fuel dispenser

technical specification

    ID Main   01H   CGDMC_ID CGD_ID Manufacturer   1   02H 01H-07H Configuration   CGDSC_ID CGD_ID System   03H 01H-11H Configuration   CGD_ERROR ERROR_ID Error   41H 01H-3FH Codes   CGD_CODE_ID CODE_ID Code ReadWrite   51H 01H-0DH Store Functions   CGD_TRANS_ID TRANS_ID Transaction   61H 01H-05H Functions  The following databases must be stored in non-volatile memory (the data may not be lost after a power down):〠fuel dispenser €ã€€ - Manufacturer Configuration.   - Code Storage.   - Transactions (when implemented).   - System Configuration.   - Error Codes.  NOTE: In case the Communication Service data base is stored in volatile memory then the Code Generating Device must   send during the system boot a broadcast heartbeat2 message with bit 1 (configuration needed) of the   DEVICE_STATUS s fuel dispenser fuel dispenser

we are committed to create the best workplace, encourage our staffs to put their own personalities into their jobs, and provide them a stage to show themselves.

    bal. © 2006 . Livedoor Melting down Jan 26th 2006 | TOKYO From The Economist print edition Arrests in the livedoor scandal AP A gripping tale in Tokyo SPEED is everything in the information-technology industry. Or so Takafumi Horie, the 33-year-old founder and ex-president of livedoor, an internet and finance company, was fond of saying. Unfortunately for him, Japan s prosecutors seemed to agree. After raiding the firm only a week ago, they arrested Mr Horie on January 23rd with unprecedented celerity. Also detained were Ryoji Miyauchi, livedoor s chief financial officer, and the presidents of livedoor Marketing, a listed affiliate, and livedoor Finance, a subsidiary. They face charges of market manipulation and accounting fraud. The alleged offences took place in late 2004, when livedoor Marketing skirted disclosure rules by announcing that it was buying Money Life, a publisher, through a share swap—when its parent company in fact already controlled the publisher through a private investment firm. It also allegedly cooked its books to show a profit instead of a loss, reportedly by transferring profits from a consumer-finance arm to boost livedoor Marketing s share price. The prosecutor s office won permission to hold the four executives at a detention centre for ten days for further questioning. With ha fuel dispenser lf of its six board members behind bars, livedoor quickly rushed to reorganise itself. Mr Horie was ousted as president and a new president appointed. He is Kozo Hiramatsu, a 60-year- old former Sony executive who founded an accounting software firm that was bought by livedoor in December 2004, after the alleged financial finagling. On January 25th Mr Horie resigned from the board. The new management faces a fearsome task. Livedoor, which is on the brink of being delisted by the Tokyo Stock Exchange, has seen roughly th fuel dispenser fuel dispenser